MIDEA 12K Four-Way Cassette Multi-Zone Outdoor Unit 25 SEER2 Series 208/230V

SKU: DLFSCAH12XAK

 

outdoor unit – model dlfscah12xak

product overview

  • series: midea four-way cassette hyper heat series
  • system type: multi-zone ductless mini-split cassette heat pump indoor unit
  • application: residential and light commercial heating and cooling
  • nominal cooling capacity: 12,000 btu/h

capacity & performance

  • cooling capacity: 12,000 btu/h
  • heating capacity:
    • 14,000 btu/h at 47°f (8.3°c)
    • 12,000 btu/h at 17°f (-8.3°c)
    • 10,500 btu/h at 5°f (-15°c)
    • 9,000 btu/h at -13°f (-25°c)
  • efficiency ratings:
    • seer2: 25.0 btu/wh
    • eer2: 12.5 btu/wh
    • hspf2: 11.0 btu/wh
    • cop at 5°f: 2.5

electrical & power

  • voltage: 208/230v, single-phase, 60hz
  • power supply: indoor unit is powered via the outdoor unit
  • power input:
    • cooling: 1,050w
    • heating: 980w
  • circuit breaker requirement: 15a
  • indoor fan motor output: 40w

refrigerant & piping

  • refrigerant type: r-410a
  • piping connection sizes:
    • liquid line: 1/4 inch
    • suction line: 1/2 inch
  • refrigerant charge:
    • pre-charged with ~32.1 oz (910 g) for a standard 25-ft line
    • additional charge required at ~0.21 oz per additional foot beyond 25 ft
  • maximum recommended piping length: 98.4 ft
  • maximum height difference: 65.6 ft

physical & mechanical characteristics

  • dimensions:
    • width: 22.44 inches (570 mm)
    • height: 10.24 inches (260 mm)
    • depth: 22.44 inches (570 mm)
  • weight:
    • net weight: ~37.5 lbs (17.0 kg)
    • gross weight: ~44.1 lbs (20.0 kg)

mounting & installation

  • mounting method: ceiling-recessed cassette installation
  • wall penetration: requires a circular opening (~3 to 3.5 inches diameter) for refrigerant piping, drain hose, and control wiring
  • clearance requirements:
    • minimum clearance of ~5.9 inches (15 cm) for return airflow
    • additional side and rear clearances required (detailed in installation manual)

control features & operating modes

  • operating modes: cool, heat, dry, fan, auto
  • key features:
    • four-way air distribution for even cooling and heating
    • built-in condensate pump for effective drainage
    • microprocessor control with wireless remote
    • auto-restart after power loss
    • refrigerant leakage detection
    • "follow me" temperature sensing (uses remote as sensor)
    • integrated, washable air filter
  • noise level: as low as ~30 db(a) in low-speed sleep mode
  • PRODUCT RESOURCES

    The following documents may not be readily available online. For specific manuals or certifications, we recommend contacting Midea customer support or an authorized Midea dealer:

    • Brochure
    • Submittal
    • Installation Manual
    • Owner's Manual
    • Service Manual
    • Parts Manual
    • AHRI Certificate
    • Extended Ratings

     

    Safety Information

    PROPOSITION 65 WARNING: This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm.

    • This unit must be installed by a licensed HVAC technician to ensure proper operation and to avoid voiding the warranty.
    • Ensure the product is connected to the correct voltage and electrical specifications to prevent electrical hazards.
    • Do not attempt to modify or service internal components without professional assistance.
    • The unit is designed to operate in temperatures ranging from -4°F to 115°F.
    • Always refer to the installation manual for detailed safety instructions.

     

     

  • PAIRING

     DLFSCAH12XAK (12K BTU) pairs with DLCSRBH12AAK (Current Loop U-match Outdoor Unit) and requires KSALG0101AAA (Accessory Kit)

bottom of page