MIDEA 12K Hyper Heat Pump Multi-Zone Outdoor Unit 25 SEER2 Series 208/230V
SKU: DLFSHCH12XAK
MIDEA 12K Hyper Heat Pump Multi-Zone Indoor Unit – Model DLFSHCH12XAK
Product Overview
- Series: Midea INFINI Hyper Heat Series (SEER 25, Energy Star)
- System Type: Multi-zone ductless mini-split hyper heat pump indoor unit
- Application: Residential heating and cooling
- Nominal Cooling Capacity: 12,000 BTU/h
Capacity & Performance
- Cooling Capacity: 12,000 BTU/h
- Heating Capacity:
- 14,000 BTU/h at 47°F (8.3°C)
- 12,000 BTU/h at 17°F (-8.3°C)
- 10,500 BTU/h at 5°F (-15°C)
- 9,000 BTU/h at -13°F (-25°C)
Efficiency Ratings
- SEER2: 25.0 BTU/Wh
- EER2: 12.5 BTU/Wh
- HSPF2: 11.0 BTU/Wh
- COP at 5°F: 2.5
Electrical & Power
- Voltage: 208/230V, single-phase, 60Hz
- Power Supply: Indoor unit is powered via the outdoor unit
- Power Input:
- Cooling: 1,050W
- Heating: 980W
- Circuit Breaker Requirement: 15A
- Indoor Fan Motor Output: 40W
Refrigerant & Piping
- Refrigerant Type: R-410A
- Piping Connection Sizes:
- Liquid Line: 1/4 inch
- Suction Line: 1/2 inch
- Refrigerant Charge:
- Pre-charged with ~32.1 oz (910 g) for a standard 25-ft line
- Additional charge required at ~0.21 oz per additional foot beyond 25 ft
- Maximum Recommended Piping Length: 98.4 ft
- Maximum Height Difference: 65.6 ft
Physical & Mechanical Characteristics
- Dimensions:
- Width: 34.65 inches (880 mm)
- Height: 12.60 inches (320 mm)
- Depth: 8.07 inches (205 mm)
- Weight:
- Net Weight: ~28.7 lbs (13.0 kg)
- Gross Weight: ~35.3 lbs (16.0 kg)
Mounting & Installation
- Mounting Method: Wall-mounted using a dedicated mounting plate
- Wall Penetration: Requires a circular opening (~3 to 3.5 inches diameter) for refrigerant piping, drain hose, and control wiring
- Clearance Requirements:
- Minimum top clearance of ~5.9 inches (15 cm) for return airflow
- Additional side and rear clearances required (detailed in installation manual)
Control Features & Operating Modes
- Operating Modes: Cool, Heat, Dry, Fan, Auto
- Key Features:
- Hyper heat functionality for enhanced low-temperature performance
- Microprocessor control with wireless remote
- Auto-restart after power loss
- Refrigerant leakage detection
- "Follow Me" temperature sensing (uses remote as sensor)
- Integrated, washable air filter
- Noise Level: As low as ~29 dB(A) in low-speed sleep mode
PRODUCT RESOURCES
The following documents may not be readily available online. For specific manuals or certifications, we recommend contacting Midea customer support or an authorized Midea dealer:
- Brochure
- Submittal
- Installation Manual
- Owner's Manual
- Service Manual
- Parts Manual
- AHRI Certificate
- Extended Ratings
Safety Information
PROPOSITION 65 WARNING: This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm.
- This unit must be installed by a licensed HVAC technician to ensure proper operation and to avoid voiding the warranty.
- Ensure the product is connected to the correct voltage and electrical specifications to prevent electrical hazards.
- Do not attempt to modify or service internal components without professional assistance.
- The unit is designed to operate in temperatures ranging from -4°F to 115°F.
- Always refer to the installation manual for detailed safety instructions.
PAIRING
DLFSHCH12XAK (12K BTU) pairs with DLFUAAH12XAK (AHU), DLFSOAH12XAK (Cassette), and DLFSDAH12XAK (Ducted)