top of page

MIDEA EVOX 18,000 BTU Heat Pump System

SKU: DLCURAH18AAK

Midea EVOX 18,000 BTU Heat Pump System – Models DLCURAH18AAK & DLFUAAH18XAK

Product Overview

  • System Type: Single-zone ducted heat pump system
  • Application: Residential heating and cooling
  • Nominal Capacity: 18,000 BTU/h

Capacity & Performance

  • Cooling Capacity: 18,000 BTU/h
  • Heating Capacity:
    • 18,000 BTU/h at 47°F
    • 12,000 BTU/h at 17°F
    • 11,000 BTU/h at 5°F
  • Efficiency Ratings:
    • SEER2: 17.0
    • EER2: 10.9
    • HSPF2: 8.8
    • COP at 5°F: 2.00

Electrical & Power

  • Voltage: 208/230V, single-phase, 60Hz
  • Minimum Circuit Ampacity (MCA):
    • System: 16A
    • Indoor Unit: 2.5A
  • Maximum Overcurrent Protection (MOP):
    • System: 20A
    • Indoor Unit: 15A

Operating Range

  • Cooling Outdoor Temperature Range: 5°F to 122°F (-15°C to 50°C)
  • Heating Outdoor Temperature Range: -22°F to 75°F (-30°C to 24°C)

Refrigerant & Piping

  • Refrigerant Type: R-410A
  • Piping Connection Sizes:
    • Liquid Line: 1/4 inch (6.35 mm)
    • Suction Line: 5/8 inch (15.88 mm)
  • Pre-Charged Refrigerant: Approximately 56.43 oz (1,600 g) for up to 25-ft line
  • Additional Charge Required: Approximately 0.54 oz/ft (50 g/m) beyond 25 ft
  • Maximum Line Length: 98.4 ft (30 m)
  • Maximum Height Difference: 65.6 ft (20 m)

Physical & Mechanical Characteristics

  • Indoor Unit Dimensions:
    • Width: 21 inches (534 mm)
    • Depth: 17.5 inches (445 mm)
    • Height: 45 inches (1,143 mm)
    • Net Weight: Approximately 78 lbs (35.3 kg)
  • Outdoor Unit Dimensions:
    • Width: 37.25 inches (946 mm)
    • Depth: 16.125 inches (410 mm)
    • Height: 31.875 inches (810 mm)
    • Net Weight: Approximately 137 lbs (62.1 kg)

Fan Performance

  • Indoor Air Flow (H/M/L): 865 / 765 / 650 CFM
  • Indoor Noise Level (H/M/L): 40 / 37 / 34 dBA
  • Outdoor Air Flow (Max): 2,700 CFM
  • Outdoor Noise Level: 59 dBA

Compressor & Fan

  • Compressor Type: Rotary
  • Refrigerant Oil: VG74
  • Outdoor Fan Motor:
    • Rated Load Amps (RLA): 1.2A
    • Power Input: 85W

Control Features & System Compatibility

  • System Operation: Supports single-zone climate control
  • Cold Weather Performance: Equipped with advanced defrost control for enhanced low-temperature operation
  • Refrigerant Leak Detection: Alerts for refrigerant issues to maintain efficiency
  • Compatibility: Designed to work with Midea EVOX indoor units

Optional Accessories

  • Wind Baffles for Low-Temperature Operation
  • Wall Mounting Brackets
  • Anti-Vibration Pads

Warranty

  • 10-year limited warranty to the original purchaser on compressor and parts upon timely registration; otherwise, 5 years.

Summary
The Midea EVOX 18,000 BTU Heat Pump System, comprising the DLCURAH18AAK outdoor unit and the DLFUAAH18XAK indoor unit, offers efficient and reliable heating and cooling solutions for residential applications. With advanced inverter technology, robust cold-weather performance, and quiet operation, this system ensures year-round comfort and energy savings. Its compact design, flexible installation options, and comprehensive warranty make it a valuable addition to any home.

  • PRODUCT RESOURCES

    The following documents may not be readily available online. For specific manuals or certifications, we recommend contacting Midea customer support or an authorized Midea dealer:

    • Brochure
    • Submittal
    • Installation Manual
    • Owner's Manual
    • Service Manual
    • Parts Manual
    • AHRI Certificate
    • Extended Ratings

     

    Safety Information

    PROPOSITION 65 WARNING: This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm.

    • This unit must be installed by a licensed HVAC technician to ensure proper operation and to avoid voiding the warranty.
    • Ensure the product is connected to the correct voltage and electrical specifications to prevent electrical hazards.
    • Do not attempt to modify or service internal components without professional assistance.
    • The unit is designed to operate in temperatures ranging from -4°F to 115°F.
    • Always refer to the installation manual for detailed safety instructions.

     

     

  • PAIRING

     DLCURAH18AAK (18K BTU EVOX Outdoor Unit) pairs with:

    DLFUAAH18XAK (Air Handler)

    DLFSOAH18XAK (One-Way Cassette)

    DLFSDAH18XAK (Slim Duct)

    DLFSCAH18XAK (Four-Way Cassette)

bottom of page