Mitsubishi 12,000 BTU Ductless Mini Split Heat Pump System – 16 SEER:

SKU: MSZ-WR12NA / MUZ-WR12NA

System Type
Single-zone ductless mini-split heat pump
Indoor Unit Model: MSZ-WR12NA
Outdoor Unit Model: MUZ-WR12NA
Application: Residential heating and cooling

Capacity & Performance
Cooling Capacity: 12,000 BTU/h
Heating Capacity: 13,600 BTU/h
Efficiency Ratings:

  • SEER: 16.0

  • EER: 9.3

  • HSPF: 8.2

Electrical & Power
Power Supply: 208/230V, 1 Phase, 60Hz
Cooling Power Input: 1,290 W
Heating Power Input: 1,410 W
MCA: 15 A
MOCP: 15 A

Indoor Unit – MSZ-WR12NA
Airflow (Lo/Mid/Hi): 177 / 294 / 412 CFM
Sound Pressure Level (Lo/Mid/Hi): 25 / 34 / 43 dB(A)
Dimensions (W x H x D): 31-7/16" x 11-5/8" x 9-1/8"
Net Weight: 22 lbs

Outdoor Unit – MUZ-WR12NA
Sound Pressure Level: 52 dB(A)
Dimensions (W x H x D): 33-1/16" x 21-5/8" x 11-1/4"
Net Weight: 77 lbs
Compressor: Inverter-driven rotary

Refrigerant & Piping
Refrigerant Type: R-410A
Factory Precharge: 25 ft
Pipe Size (Liquid / Gas): 1/4" / 3/8"
Max Piping Length: 65 ft
Max Height Difference: 40 ft

Operating Range
Cooling: 14°F to 115°F
Heating: 5°F to 75°F

Key Features

  • Inverter technology

  • Auto restart

  • ECONO COOL mode for energy-saving comfort

  • Dehumidification mode

  • Blue fin anti-corrosion treatment

  • Compact and quiet design

  • No Wi-Fi in this model

  • PRODUCT RESOURCES

    The following documents may not be readily available online. For specific manuals or certifications, we recommend contacting Mitsubishi customer support or an authorized Mitsubishi dealer:

    • Brochure
    • Submittal
    • Installation Manual
    • Owner's Manual
    • Service Manual
    • Parts Manual
    • AHRI Certificate
    • Extended Ratings

     

    Safety Information

    PROPOSITION 65 WARNING: This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm.

    • This unit must be installed by a licensed HVAC technician to ensure proper operation and to avoid voiding the warranty.
    • Ensure the product is connected to the correct voltage and electrical specifications to prevent electrical hazards.
    • Do not attempt to modify or service internal components without professional assistance.
    • The unit is designed to operate in temperatures ranging from -4°F to 115°F.
    • Always refer to the installation manual for detailed safety instructions.

     

     

bottom of page